Adjusted power
Motion detector
Power variation with movement detector
Pre-requisites
Luminaires with programmable electronic driver using DETECT option
Limits
Minimal power 16% – Timing from 30s to 1h30
Street light height between 4 and 6m
Turning off of the luminaire not possible
Connection to other functions possible
BP8 or BP6 program – P-Adjust – F-Constant
Performance
Allows lighting variation according to detection
The captor is installed on the luminaire
Default timing 3mn
30% threshold without detection. 100% threshold with detection
Motion detector characterictics
Detection distance: 10m max
Detection zone: 80 zones
Target speed of movement: 1.2 to 5.4km/h
Target size: human body, i.e 700 x 250mm
P-Adjust
Adjust the lighting for optimal display
Pre-requisites
Luminaires with programmable electronic drivers using P-Adjust programs
Limits
Minimal power 16%
Connection to other functions possible
Color Cycle program – Var – F-Constant
Performance
Allows to adjust the LED power of a luminaire from 5 to 5W
Example: P-Adjust 70W is a 94W module adjusted to 70W power
F-Constant
Power Adjustable to time
Pre-requisites
Luminaires with programmable electronic drivers using F-Constant programs
Connection to other functions possible
Color Cycle program – P-Adjust - Var
Performance
Allows to have a constant outgoing flux from the luminaire
Compensates flux depreciation of LED or the luminaire
Other SmartLum options
-
Point to point control
Define the correct local amount of brightness in the right place, at the right time.
-
Autonomous group
Ensure control of lighting points. Each point able to operate as a pilot.
-
Group management
Ensure control of lighting points from a grid.
-
Management of lighting points
Control the amount of brightness at the right place and the right time and ensure monitoring of each lighting point.